ACV - excellence in hot water
Home
ACV technology
Products
About ACV
News
Documentation (PDF)
Contacts
Home  >  ACV Products
Back 

 HeatMaster® 35TC–85TC...

Condensing Range

Total condensing storage combination boiler -
complies with Part L.

With the high levels of building insulation now in place in most properties, the requirements for heating output are reducing – and this trend is set to continue with some experts predicting a drop in the boiler load due to heating from around 75% to as low as 45%. At
the same time, hot water usage is increasing year-by year as demand rises for luxury bathing facilities such as high performance showers and spa baths. If hot
water demand has risen to 55% of the boiler load, the natural next step is to gain as much efficiency in hot water mode as possible.

MCBA electronic control fitted as standard. Managing boiler and burner functions, this helps reduce the stop/start cycle significantly, ultimately saving fuel and component wear and tear.

Additional controls available, please discuss your requirements with our technical department.

Dimensions

 

Technical Data

HM35-85

HM35TC

 

HM85TC

 

 

NAT GAS

LPG

 

NAT GAS

LPG

Input max/min

kW

34.9/10.0

30.6/10.0

 

85.0/17.2

85.0/17.2

Output max/min

kW

34.1/9.8

29.9/9.8

 

82.5/16.5

82.5/16.5

Efficiency hot water mode

%

105.9

105.9

 

105.0

105.0

Efficiency heating mode

%

108.5

108.5

 

108

108

SAP seasonal efficiency

%

90.9

92.6

 

-

-

Total capacity

L

189

189

 

315

315

Primary capacity

L

108.5

108.5

 

125

125

Gas connection (male)

Æ

3/4"

3/4"

 

1"

1"

Primary flow & return connection

Æ

1"

1"

 

1 1/2"

1 1/2"

Secondary hot water Connection

Æ

1"

1"

 

1 1/4"

1 1/4"

Flue connection

Æ mm

80/125

80/125

 

100/150

100/150

Max length concentric flue

mtr

20   

20   

 

20   

20   

Nox class (EN483)

 

class 5

class 5

 

class 5

class 5

Weight empty

kg

174   

174   

 

284   

284   

Natural gas flow rate - 20mbar

m3/h

3.7

 

 

8.99

 

Pressure drop

mbar

30

30

 

200

200

Maximum operating temperature

°C

90

90

 

90

90

 
 
 
Performance Data   HM 35TC HM 85TC
     

Litres in first 10 minutes 

40°C

419

850

Litres in first 10 minutes 

45°C

381

722

Litres in first 10 minutes 

60°C

224

459

Litres in first hour

40°C

1312

3177

Litres in first hour

45°C

1080

2717

Litres in first hour

60°C

692

1778

Continuous flow 40°C

Ltrs/hr

1057

2793

Continuous flow 45°C

Ltrs/hr

898

2394

Continuous flow 60°C

Ltrs/hr

578

1583

 

 

Heating
The heating return enters the lower
circuit of the boiler, which allows the
boiler to operate in condensing mode.
The upper circuit of the HeatMaster TC
is kept at a consistently high
temperature due to the internal shunt
pump which ensures that the primary
water circulates around the heat
exchanger flue tubes

Hot Water
With the upper circuit maintained at a
high temperature, the HeatMaster TC
is always ready to supply hot water on
demand. The cold water enters
through the dual coil at the base of
the heat exchanger and is pre-heated
before entering the hot water tank.
The low temperature of the bottom
circuit results in continuous
condensation of the flue gases in hot
water mode.

Heating and Hot Water
Once up to temperature, the
HeatMaster TC is capable of producing
heating and hot water simultaneously.

Site map | Legal notice | Glossary | FAQ
Contact ACV